Fire watch: keep your building open while the sprinklers are down

When a sprinkler or alarm system goes down, or a tall building goes up, California's fire code can require a fire watch. Set one up quickly and the building stays open while the repair is made.

By CSUSA SecurityNovember 20266 min read

A fire watch officer walking an apartment corridor with a log

A fire watch is a trained person who walks your building looking for fire while its fire protection is not working. It is how a building stays open, and how a job site stays legal, when the sprinklers, the alarm or the water supply are out of service.

The rules come from the California Fire Code and the California Building Code, and your local fire department enforces them. The fire code official has the final say on when a watch starts, how it runs and when it ends.

When California requires a fire watch

Most fire watches start for one of two reasons.

  • A required fire protection system is out of service. Under California Fire Code Section 901.7, the fire code official can order the building evacuated or require an approved fire watch until the system is back.
  • A building is under construction. California Building Code Section 3314 requires a fire watch during nonworking hours on construction over 40 feet tall, and on new multistory construction above 50,000 square feet per story, or wherever the fire code official requires one.

Sprinkler impairments are the most common trigger in occupied buildings. NFPA 25, which California adopts, calls for a fire watch when an automatic sprinkler system is out of service for 10 hours in a 24-hour period. Fire departments also order watches after a fire, during alarm panel replacements, and when a fire pump or water main is down.

Rules differ by city and by building type. Hospitals, for example, follow additional state requirements. Ask your fire department what they expect before the watch starts, and get their answer in writing.

What a fire watch officer does

A fire watch has one job: walk the building, find fire early and get the fire department there. The officer is not there to guard the lobby or check visitors at the same time.

  • Patrols every floor, stairwell and mechanical room on a set route, usually at least once an hour.
  • Checks for smoke, heat, sparks, blocked exits and anything that could start a fire.
  • Keeps a written log of every round, with the time and what was checked.
  • Carries a phone or radio to call 911 and wakes the building if there is a fire.
  • Stays on post until relieved by another officer or until the fire department ends the watch.

What the fire department will ask for

Inspectors look at the log first. It should show the officer's name, the time of every round, the areas checked and anything found. Many departments also want to know who to call if the watch is missed, and they expect the watch to continue around the clock until they approve ending it. Some accept the end of a watch only in writing.

Keep the log on site where an inspector can read it. If the watch runs for weeks, keep the old pages too.

What it costs to wait

When a required watch is not in place, the fire code official can order the building evacuated. For a residential tower that means residents leave their homes. For an office or a hotel it means closing until the system is repaired or a watch is posted. Setting up the watch is almost always the cheaper choice.

How to set one up

  • Call the fire department and the sprinkler or alarm contractor, and ask how long the repair will take.
  • Book officers for every hour the system is down, nights and weekends included.
  • Agree on the route, the round frequency and the log format with your fire department.
  • Give the officers keys or access to every floor, stairwell and roof door on the route.
  • Keep the watch going until you have written approval to stop.

CSUSA posts fire watch officers for occupied buildings, job sites and properties recovering from fire damage. Officers keep the log your fire department asks for, and a supervisor checks the post. See Fire Watch for how it works, or call us to staff one.

Questions

How long does a fire watch last?

Until the fire department approves ending it, usually after the system is repaired, tested and back in service. Plan for the full repair time, including nights and weekends.

Can our own staff do the fire watch?

Some fire departments allow it if the person is trained and does nothing else during the watch. Many buildings hire officers so staff can keep doing their jobs. Ask your fire department what they accept.

Does a fire watch replace the sprinklers?

No. It is a temporary measure while the system is repaired. The building still needs working fire protection.

How fast can CSUSA start a fire watch?

Call us with the address, the system that is down and how long the repair will take, and we will tell you what we can staff and when.

More from the blog

Next step

Tell us about your building.

Talk to a security expert

Or call (888) 804-7060

Awards and affiliations

  • ASTORS 2023 Gold Award Winner, American Security Today Homeland Security Awards
  • Training magazine APEX Awards
  • MVAA Veteran-Friendly Employer, Gold 2025
  • Newsweek America's Greatest Workplaces for Diversity 2025
  • America's Best Workplaces 2025, certified by Best Companies Group
  • Member of the Beverly Hills Chamber of Commerce